navien 3
Data Field NPE-210S
Heat Capacity (Input) Natural Gas 19,900-180,000 BTU/h
Propane Gas 19,900-180,000 BTU/h
Efficiency Ratings UEF (for NG & LP) 0.97
EF (Canada) (for NG & LP) 0.99
Flow Rate (DHW) 35⁰F(19⁰C) Temp Rise 10.1 GPM (38 L/m)
45⁰F(25⁰C) Temp Rise 7.8 GPM (30 L/m)
67⁰F(36⁰C) Temp Rise 5.2 GPM (20 L/m)
Dimensions 17.3"(W) x 27.4"(H) x 13.2"(D)
Weight 75 lbs (34kg)
Installation Type Indoor or Outdoor Wall-Hung
Venting Type Forced draft direct vent
Ignition Electronic Ignition
Water Pressure 15-150 PSI
Natural Gas Supply Pressure (from source) 3.5"-10.5" WC
Propane Gas Supply Pressure (from source) 8"-13" WC
Natural Gas Manifold Pressure (min to max) -0.04" WC to -0.36" WC
Propane Gas Manifold Pressure(min to max) -0.02" WC to -0.66" WC
Minimum Flow Rate 0.5 GPM (1.9 L/m)
Connection Sizes Cold Water Inlet 3/4" NPT
Hot Water Outlet 3/4" NPT
Gas Inlet 3/4" NPT (suitable for use with 1/2" rigid gas pipe; refer to installation manual for sizing criteria)
Power Supply Main Supply 120 V AC, 60Hz
Maximum Power Consumption 200 W (max 2A), 350W (max 4A) with external pump connected
Materials Casing Cold rolled carbon steel
Heat Exchangers primary and secondary heat exchangers: stainless steel
Venting Exhaust 2" or 3" PVC, CPVC, polypropylene 2" or 3" special gas vent type BH (Class II, A/B/C)
Intake 2" or 3" PVC, CPVC, polypropylene 2" or 3" special gas vent type BH (Class II, A/B/C)
Vent Clearances 0" to Combustibles

Get Yours Now!

Get your new Navien Tankless Water Heater today!